Quantcast
Channel: Counter/Timer topics
Browsing all 1250 articles
Browse latest View live

flowmeter on usb 6009 (connections)

Hello, I am using a flowmeter (attached) on a USB 6009. The wiring connections (3 wires from flowmeter) are:Sig ground to GRD of the module+Vdc to the +5V of moduleSignal output to the PFI0 of...

View Article


Image may be NSFW.
Clik here to view.

DAQmx CreatePulseChannelTimeMethod

Dear all, I am trying to setup a digital counter using a NI-DAQmx card and using VS-C#.  My question comes when I declare the GateTask. So, I do: GateTask.COChannels.CreatePulseChannelTime("Dev1/ctr0",...

View Article


counter miss TELL pulses, NI DAQmx 9181 with NI 9402

Hi,I am trying to read TTL pulses from a function generator using a counter. I am applying a 1KHz signal to the counter. Every time counter reads the pulses correctly in first cycle of measurement, but...

View Article

Drive CO Timing Off of Non-TTL Clock?

Hi, I'm using a PCIe-6321. I'm trying to send a counter output for specified numbers of ticks based on an external clock coming into a PFI input. The problem I'm having is that my external signal is...

View Article

How to I determine when my Two edge separation counter starts counting

I've been searching through a ton of Daqmx properties, the, web and the NI-forum to find the answers to the question "How do I determine when my Two-Edge Separation Counter actually starts counting. So...

View Article


usb 6341 counter number of buffer

HiI will use usb 6341 to measure digital pulse.What is maximum buffer when i use 25Mhz sample clock with buffered mode? (It shown error when i set 25Mhz clock, N sample mode, 1M sample)Is there any...

View Article

USING TWO COUNTERS TO COUNT INDEPENDAN EVENTS

Hi Group,Been searching an trying many things to find a solution.  I know there is one but just can't seem to get it right. I have two devices which supply TTL pulses which I need to count.  Ctr 1 will...

View Article

DAQ timing

Hello, I'm trying to make a program that uses a switch to change between a low resistior and a high resistor. The object is to detect when a current has changed significantly to change to a different...

View Article


cDAQ-9181 with NI 9402 : After first read cycle Counter is missing some...

Hi,I am trying to read TTL pulses from a function generator using a counter. I am applying a 1KHz signal to the counter. Every time counter reads the pulses correctly in first cycle of measurement, but...

View Article


single pulse width measurement

Hello, I am trying to measure the time of a single pulse using ctr0 on a PXIe-6361. The input signal seen in attachment Capture7.jpg, is going to PFI 9, the gate of ctr0. The problem is that the...

View Article

Problem using single counter on NI9411

I'm trying desperaterly to get 3 Period measurements on a single 9411 module.  I'm measuring ranges from 0 - 5000 hz, I'm able to do this accurately using the high frequency, two counter period...

View Article

NI 6023E counter Trigger

Hi All, I am using NI 6023E DAQ. I am trying to start the analog measurement and the pulse count measurement (PFI8) after the triggering from PFI5. Counters can only be triggered with ARM triggers. But...

View Article

How can I increase sampling rate? Active Noise Cancellation

HelloI am an undergraduate working on building Active noise cancellation code. I could make good secondary path filter FPGA code (which could generate maximum 7k sampling rate). However, my second FPGA...

View Article


fpga

Hola amigos, por preguntales como puedo medir el tiempo entre flancos con una myRIO, o con la FPGA que esta en la myRIO, cualquier ayuda sera bien venida 

View Article

CO Pulse Ticks waveform

Hello, I am using an NI USB-6353 and Labview 2013. I would like to be able to use the CO Pulse Ticks along with the Start Digital Edge functions in order to create a digital waveform graph. My hope is...

View Article


counter reseting after particular number is reached

Hi, I need a counter which will count from 1 to 20. It should reset at 20 and again start from 1 again. Can any one help me in this. Also I need how to interface the labview simulation with real time...

View Article

Problème de pretrig Analogique

Bonjour, Voila mon problème : Je dispose actuellement d'une carte NI PCI 6254 mais je pense qu'elle n'est pas suffisante. En effet, je veux analyser (enfin du moins capter) 4 impulsion analogique en...

View Article


moved

moved!

View Article

PXI-6624 custom device

Hello, Sorry for my bad english. I start with the custom device. I want use two PXI-6624 with Veristand for counter I/O. So I try to creat two easy custom device, one for each card. The program is ok...

View Article

Fluctuation observed while measuring frequency through "NIDAQmx" library for...

We have tried all the APIs mentioned in the attachment for measuring frequency by using NI-6014.Significance difference was observed between the Set frequency and the measured frequency.Please provide...

View Article