Quantcast
Channel: Counter/Timer topics
Browsing all 1271 articles
Browse latest View live

measuring counter periodicaly

Dear all, So I have a counting edges task :DAQmxCreateCICountEdgesChan(aoTask, "Dev1/ctr1", "", DAQmx_Val_Rising, 0, DAQmx_Val_CountUp);wich I can interogate by the click of a button...

View Article


Multiple edge separation measurement

I wondered if someone could tell me if this was possible or how I might set it up if it were. I want to do a variation of Two-Edge Separation measurement with an NI PCI 6602 and DAQ-mx, but with...

View Article


Image may be NSFW.
Clik here to view.

Simple Period Measurement

Hopefully this will be an easy one for somebody, but working on site under pressure and I can't see what is wrong  I have a PCI-6351 card and I am testing it with NI-MAX, I setup a simple task to...

View Article

Counter clock from PXI

Hello, I thought it is a simple problem but still I was not able to solve it. I have a very generic counter VI as shown in the snippet.The counting signal is a non-periodic TTL. The VI fails if this...

View Article

Fast simultaneous edge counting without stopping the task

Hi all,I am trying to do edge counting with two counters simultaneously. The idea is to use them for photon counting application with two detectors. For this I use the third counter for...

View Article


External sample clock with encoder

Hi everybody, I have an external encoder wired to a 9423 module on a 9185 chassis, where i count the impulses of the encoder using channel A and B.I also have some sensors connected to a 9205 analog...

View Article

contador de tiempo y suma de paro

Buenas noche e logrado hacer un contador de tiempo transcurrido, como por parte de proyecto de  la universidad esto lo e hecho con el shif register pero a donde quiero llegar es que también  el...

View Article

How to use counters NI 6363

HiI got to use the counters on the NI 6363. My problem is, I got a nearly full card.So my question is. If I use a counter out i.e. CTR 1 OUT, can I use the other pins (CTR 1 Aux/SRC/Gate) for some...

View Article


DAQmx large range 2 counter frequency measurement 1 count off error

I'm using a NI PXI-6229 to measure a 32.768kHz RTC ref clock. I'm setup in MAX with a task using the largerange2 counter frequency  measurement, as I need a very precise measurement. Every say, 1 in 30...

View Article


Taking time measurements when measuring frequency

I am needing to read the frequency of a TTL signal as part of a data acquisition program that also records analog voltage (at 6 kHz). I've looked at the shipping examples for Counter - Read...

View Article

Using NI 9205 module, external trigger into the PFI0 input.

I'm trying to put my external trigger into the PFI0 digital input.   When I connect up my hardware clock, it loads down my signal.  After putting a DC meter on the PFI0 line, open ckt, I see 1.85vDC...

View Article

PWM input with CompactDAQ & LabWindows

I need to measure the pulse width of a 244Hz PWM signal using CompactDAQ.  Is there a white paper or tech note out there to help me set this up?

View Article

Can't read data for the same lap from two counters

HiI am using NI 6624 counter board and building an app in C#. I have one counter (0) which counts edges of Index pulse (Z) from a Angle encoder and triggering on PFI4 on rising edge of Z pulse. Where I...

View Article


Image may be NSFW.
Clik here to view.

NI 9411 Continuous Edge Counting - external sample clock

Hi  I have a DAQ setup that uses the following:Chassis NI cDAQ9188NI 9411Quadrature Encoder I want to make continuous buffered measurement of position reading from the quadrature encoder. I first set...

View Article

Image may be NSFW.
Clik here to view.

DAQmx Channel Property node for mixed counter task, error 200452

Hi Folks, I've a task where I'm measuring 4 frequencies and 1 encoder (A/B).I want to enable and set the filter on the frequency channels. This works, if I remove the encoder channel from the task, but...

View Article


Image may be NSFW.
Clik here to view.

2 finite pulse generation by a counter triggered by one counter

Hi guys,I am using NI USB-X 6353 and 6343 for a test system. I need two sequential pulses from a counter after triggering it with another counter on the same board. I would like to start the trigger...

View Article

can't run example of DigPulseTrain-Cont-Buff-ExtClk

Hi all, I was trying to run NI DAQmx example of "DigPulseTrain-Cont-Buff-ExtClk", but there is an error generated once the external clock is supplied at frequency of 1 Hz as specified in the example....

View Article


[NI 9361] Dynamic Averaging on Period Measurements not working as expected

I am trying to demodulate a frequency modulated square wave by using a NI 9361 counter on a NI 9174 chassis. I am measuring the period length in ticks, but it is always quantized at 2k ticks. At lower...

View Article

PXI-6602 Counters

I am using a PXI-6602 card connected to a SCB-68 break out.  I am able to generate an output from CNTR 0 and CNTR 1.  None of the other counters 2 thru 7 appear to work.  I monitor their outputs with a...

View Article

Counter logic confirmation

G'day, I'm coming here from this post, with the aim of confirming my understanding of counters in Labview. I've tried to build stable, accurate square wave output waveforms using software timing, which...