PCI-6602 routing limitation

$
0
0

I am trying to use 4 counters to generate 4 signals, synchronized with external trigger (PFI 38). If I use counters 0 to 3, it fails to build a route connecting counter 0 internal output with start trigger of counter 1. - as on attached snippet.

If I use any other counter (4 to 7) instead of counter 0, it works fine.

I could not find anything forbidding the first configuration in NI Max device routes table. It shows only ArmStart trigger connections, they are directly connected to counters' internal outputs if in the same half (0-3 or 4-7) and through trigger bus if in the other. 

Is there a way to develop a configuration like that without trying? Am I reading something wrong, is there complete routing documentation somewhere? 

 