Understanding Circuit Timing/Tolerance

$
0
0

AI, 0 - 100mVdc (5V common)

Pressure Transducer (PT), Unit=PSI

7

krispiekream_0-1652455160483.png

 

I am trying to understand why these values were used.

why didnt they don't just use 

0 mV

25 mV

75 mV

100 mV

 

why 

0 mV

25.3 mV

75.6 mV

100.9 mV

 

Given the requirements below. 

If someone can guide me, it would greatly appreciated. thank you

 

Pressure Transducer Signal Requirement Tests

              

Test #

Card #

Signal #

Signal Name

Input (mV)

Expected (mV)

Tol (±mV)

L Limit (mV)

H Limit (mV)

Note

 

1

1

 

0

0.000

1.000

-1.000

1.000

 

 

1

2

 

0

0.000

1.000

-1.000

1.000

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

25

25.000

2.000

23.000

27.000

 

 

1

2

 

25

25.000

2.000

23.000

27.000

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

50

50.000

2.000

48.000

52.000

 

 

1

2

 

50

50.000

2.000

48.000

52.000

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

75

75.000

2.000

73.000

77.000

 

 

1

2

 

75

75.000

2.000

73.000

77.000

 

 

 

 

 

 

 

 

 

 

 

 

1

1

 

100

100.000

2.000

98.000

102.000

 

 

1

2

 

100

100.000

2.000

98.000

102.000

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

0

0.000

1.000

-1.000

1.000

 

 

2

5

 

0

0.000

1.000

-1.000

1.000

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

25

25.000

2.000

23.000

27.000

 

 

2

5

 

25

25.000

2.000

23.000

27.000

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

50

50.000

2.000

48.000

52.000

 

 

2

5

 

50

50.000

2.000

48.000

52.000

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

75

75.000

2.000

73.000

77.000

 

 

2

5

 

75

75.000

2.000

73.000

77.000

 

 

 

 

 

 

 

 

 

 

 

 

2

4

 

100

100.000

2.000

98.000

102.000

 

 

2

5

 

100

100.000

2.000

98.000

102.000

 

              

 

The pressure transducer circuit SHALL handle the maximum pressure transducer differential input voltage range of 0 mV to +105 mV for the circuits allocated to the pressure transducers used for  control.

 

 

The pressure transducer circuit will handle the maximum pressure transducer differential input voltage range of 0 mV to +133 mV for the circuit allocated to the pressure transducer that reports accumulator pressure, if used.

The pressure transducer circuit will handle the maximum pressure transducer differential input voltage range of 0 mV to +133 mV for the circuit allocated to the pressure transducer that reports supply pressure.

Pressure Transducer Circuit Timing/Tolerance Requirements

 

The pressure transducer circuit SHALL have an accuracy of ±0.3 mV or better between the pressure transducer differential analog input to digital data output.

 

The pressure transducer circuit SHALL resolve the pressure to 0.1 mV increments as digital data output.

 

 

 